All required data reaches the driver - After clicking “Show details” near driver status on the configuration page, all sources (DTrack, HMD Imu, Platform Imu) should be displayed in green. The below screenshot shows a sitatuation where the connection of the Platform Imu should be varifiedverified.
...
Some troubleshooting suggestions:
If the DTrack indicator is not green please make sure that DTrack is running and that the Output settings in DTrack and the port number configured for the LPVR driver are correct and agree. If you are working in a restricted IT environment, you may have to select “act as router for tracking output” in DTrack’s output settings.
If the indicator for the platform IMU is red, make sure its USB cable is connected and restart Varjo Base. We discuss its setup in detail further down.
If the headset IMU indicator is red, please restart Varjo Base. If it remains red, please make sure Varjo Base doesn’t display any errors.
Expand | ||
---|---|---|
| ||
If the system misbehaves it may be useful to look in more detail to isolate which part is failing. In particular the motion can be subdivided into the following parts which can be validated separately.
|
Adjustment of Platform IMU
...