LPMS-U3 Hardware Manual

System Overview

System Architecture

 

Pinout Description

 

Pin

Name

Function

1

VCC

+5V~18V

2

CAN_L

CAN_L Signal

3

RES

Reserved

4

RES

Reserved

5

GND

Ground

6

GND

Ground

7

CAN_H

CAN_H signal

8

RES

Reserved

9

RES

Reserved

Pin

Name

Function

1

VCC

+5V~18V

2

RS232_TX

RS232 Transmit

3

RS232_RX

RS232 Receive

4

RES

Reserved

5

GND

Ground

6

GND

Ground

7

RES

Reserved

8

RES

Reserved

9

RES

Reserved

Pin

Name

Function

1

VCC

+5V~18V

2

RES

Reserved

3

RES

Reserved

4

UART_RX

TTL Receive

5

GND

Ground

6

GND

Ground

7

RES

Reserved

8

UART_TX

TTL Transmit

9

RES

Reserved

Please note that TTL, RS232 and CAN Bus pins are mutually exclusive. Only one communication interface is enabled depending on the model. Communication interfaces for different LPMS-U3 models are listed below:

Model

Communication Interface

USB

RS232

CAN

TTL

LPMS-UR3

✓

✓

×

×

LPMS-CU3

✓

×

✓

×

LPMS-UTTL3

✓

×

×

✓

Default settings for communication interface:

  • USB: USBXpress, convertible to virtual COM port,921600bps,8N1 

  • RS232: 921600bps,8N1

  • CAN: 500kbps, terminal resistor enabled

Coordinate System

The coordinate system for LPMS-U3 is defined as follow:

 

Accelerometer output convention

A positive acceleration output will be produced when the sensor is accelerated at the same direction of the positive axes. When the sensor is at rest with Z axis pointing upwards, the calibrated output of the accelerometer is expected to be [0 0 +1g] indicating the acceleration due to the force of gravity.

Gyroscope output convention

Gyroscope output follows the right hand rule where rotation along an axis following the right hand convention will produce a positive angular velocity. The calibrated output of the gyroscope is expected to be close to zero when the sensor is at rest.

Magnetometer output convention

XYZ axes indicates the direction of magnetic field that generates a positive output reading in normal measurement configuration.

Euler output convention

Euler output is in degree. The rotation sequence follows global XYZ rotation. In other words, the current orientation of the sensor can be obtained by rotating at the euler values along global X → global Y → global Z axis.

Range of euler output is as follow:

  • X Angle: -180° ~ +180°

  • Y Angle: -90° ~ +90°

  • Z Angle: -180° ~ +180°

Specifications

Main Parameters

Parameter

Value

Euler angle range

X: ±180°;Y: ±90°;Z: ±180°

Angle resolution

0.01°

Output data type

Raw and calibrated imu data / Euler angle / Quaternion / Linear acceleration / Angular velocity / Temperature / Pressure

Communication interface

CAN BUS

UART: RS232/ TTL

USB

Max. baudrate

1M bps

921600 bps

921600 bps

Communication protocol

CANOpen

/SequentialCAN

LPBUS

LPBUS

Dimensions

34.5x34x15.7 mm

Weight

~17.6g

Max. data output rate

500Hz

Power consumption

LPMS-CU3: 0.025A @12V

LPMS-URS3: 0.029A @12V

LPMS-UTTL3: 0.016A @12V

Power supply

5V~18V DC

Operating temperature range

-20~+80 °C

Connector

DB9(female) / micro-USB type B

Accelerometer Parameters

Parameter

Value

Unit

Measurement range

±2/±4/±8/±16

g

Linear acceleration sensitivity

0.061/0.122/0.244/0.488

mg/LSB

Linear acceleration sensitivity change vs temperature

±0.01

%/°C

Linear acceleration zero-g level offset accuracy

±10

mg

Linear acceleration zero-g level change vs temperature

±0.1

mg/°C

Acceleration noise density

60

μg/√Hz

Gyroscope Parameters

Parameter

Value

Unit

Measurement range

±125/±250/±500/±1000/±2000/±4000

dps

Angular rate sensitivity

4.375/8.75/17.50/35/70/140

mdps/LSB

Angular rate sensitivity change vs temperature

±0.007

%/°C

Angular rate zero-rate level

±1

dps

Angular rate zero-rate level change vs temperature

±0.005

dps/°C

Rate noise density

5

mdps/√Hz

Magnetometer Parameters

Parameter

Value

Unit

Measurement range

±2/±8

Gauss

Sensitivity

3000/12000

LSB/G

Zero offset

±10

mG

Linearity

0.1 (FS=±2 gauss)

%FS

Packaging details

Â