Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Starting DTrack

  • Before starting DTrack make sure camera and computer are in the same subnet. Only then DTrack will see your camera controller.

image-20241104-064741.pngImage Removedimage-20241104-064741.pngImage Added
  • If needed change the camera configuration by inserting a USB memory into the camera controller or Smarttrack 3 camera. A config file will be written onto the stick. Edit the config file and re-insert stick to reconfigure. For more information consult the manual that came with your ART system.

  • Start data acquisition by pressing the Start button. Note that to access any item from the menu to configure e.g. the body configuration you need to stop acquisition first.

image-20241104-064239.pngImage Removedimage-20241104-064239.pngImage Added

Room Configuration

  • In the room calibration in DTrack the Y axis should be pointing up. This can be done wither without a room calibration triangle:

image-20241104-090011.png
  • Or with a calibration triangle:

image-20241104-090146.png

Outputting Data to FusionHub

  • DTrack needs to be specially configured to send data to the correct IP address and output port. Find the IP address of your headset either in the HMD’s WIFI configuration.

image-20241104-081159.pngImage Removedimage-20241104-081159.pngImage Added
  • In the DTrack output settings enter the IP address of your headset.

image-20241104-070710.png

Correct Body Configuration

  • Attach the marker target to your headset

  • Open the body administration dialog:

image-20241104-081813.pngImage Removedimage-20241104-081813.pngImage Added
  • In the body calibration dialog load the body file for your HMD:

image-20241104-082418.pngImage Removedimage-20241104-082418.pngImage Added
  • Leave the configuration dialog by pressing the exit button and start data acquisition. When the HMD target is in the tracking volume it should be recognized similarly to what’s shown below.

image-20241104-082828.pngImage Removedimage-20241104-082828.pngImage Added

Example of Correct Body Configuration

  • Optical target for Quest Pro, front, side and top view with corresponding body configuration view in DTrack:

image-20241104-084858.pngimage-20241104-084919.png
image-20241104-084932.png

image-20241104-084941.png

image-20241104-085001.png

image-20241104-085013.png

  • The axis arrangement must be according to the SteamVR coordinate system: