Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 5 Current »

Adjustment for LPVR-DUO

By default low pass filtering is applied to LPMS-IG1 gyroscope output. This improves the quality of the signal for applications with slow rotations. In case of faster rotations e.g. in a motion simulator it is recommended to change the low-pass filter settings for the sensor to become more responsive. Please follow the steps below to do this:

  • Save sensor settings file from sensor

    • Open IG1Control

    • Connect to LPMS-IG1

    • Go to menu bar → Settings → Save settings to file

  • In the file you saved, change G1F to 2500 as shown below:

  • Save file in the editor

  • In IG1-Control reload the settings file: menu bar → Settings → Load settings from file

  • Save settings to sensor: menu bar → Settings → Save parameters to sensor

  • Power cycle. The sensor should now respond faster to orientation changes.

Generally Available Settings

NOTE: These extended settings are usually not required for optimum LPVR-DUO performance.

In the settings file the following lines can be edited to change the filter settings for LPMS-IG1 gyroscope and accelerometer:

Possible accelerometer / gyroscope settings:

  1. Accelerometer settings:

    • AR (accelerometer range, g): 2, 4 (default), 8, 16

    • AOR (accelerometer data output rate, Hz): 3, 7, 15, 31, 62, 100 (default), 125, 200, 250, 500, 1000

    • AF (accelerometer 3-dB bandwidth, Hz): 5, 10 (default), 21, 45, 99, 218, 420

  2. Gyroscope settings:

    • GR (gyro range, dps): 400 (default), 1000, 2000

  3. Gyroscope I (high precision) settings:

    • G1OR (gyro data output rate, Hz): 100, 200, 400, 800, 1600, 3200, 6400, 12800 (default)

    • G1F (gyro low pass filter): value of G1F is calculated as LpfOrder*1000 + LpfFrequency

      • LpfOrder (low pass filter order): 2, 3, 4 (default)

      • LpfFrequency (low pass filter cutoff frequency, Hz): 10 (default), 35, 45, 50, 70, 85, 100, 140, 175, 200, 285, 345, 400, 500

      • Default value: 4*1000 + 10 = 4010

  4. Gyroscope II (High range) settings:

    • G2OR (gyro data output rate, Hz): 3, 7, 15, 31, 62, 100 (default), 125, 200, 250, 500, 1000

    • G2F (gyro 3-db bandwidth, Hz): 5, 10 (default), 20, 41, 92, 176

IMPORTANT: Please make sure AOR and G2OR settings are the same. This is because the accelerometer and gyroscope II belongs to the same chip and share the same data output rate. In case of different values, G2OR value will be used to set the chip data output rate.

  • No labels