Optitrack Motive Setup

Calibration

Camera Calibration

  1. Move all markers out of the view of cameras.

  2. Go to View → Camera Calibration Pane. Then go to “Calibration” tab.

  3. Prepare the Optitrack calibration wand, and click the buttons below to start calibration. Check if the correct wand type is selected.

  4. After wanding, click Calculate to calibrate the camera.

 

OptiTrack Axes Configuration

  1. Go to “Ground Plane” tab under “Camera Calibration Pane“ from the previous section.

  2. Place the Optitrack Axes Tool according to your intended axis directions into camera’s view. Then click “Set Ground Plane”.

Add a new tracking body

  1. Go to View → Builder Pane. Go to Create tab.

  2. Select the tracking object in the Perspective View

  3. Give the tracking body a name

  4. Click “Create”

Tracking Body Axes Configuration

  1. Go to View → Builder Pane. Then go to Edit tab.

  2. Select tracking object in the Perspective View.

  3. Rotate it to a desired orientation and click reset button under “Orientation” section.

  4. You can also click “Start” to refine the body tracking.

5. Go to View → Info Pane. Select the tracking body in the Perspective View. You can find your real-time tracking output.